HomeMy WebLinkAbout483311 "4/s PUTNAM COUNTY DEPARTMENT OF HEALTH DIVISION OF ENVIRONMENTAL HEALTH SERVICES DESIGN DATA SHEET - SUBSURFACE SEWAGE TREATMENT SYSTEM Owner Address .z & Located at (Street) 2 & 0 At e-J�a n. Tax Map AV-1 9 Block Lot (indicate nearest cross street) Municipality R4 776. a .t o,,, Watershed SOIL PER: COLATION TEST DATA l Date of Pre - soaking Date of Percolation Test s/ 7/0' y 2% 2 _� i z ,y 3i :Jz < < 2 3 4 5 1 . 2 3 4 5 1 2 3 4 5 NOTES: 1. Tests to be repeated at same death until arwroximately eaual percolation rates are obtained at each percolation test hole. (i.e. s 1 min for 1 -30 min/inch, s 2 min for 31 -60 min/inch) All data to be submitted for review. 2. Depth measurements to be made from top of hole. Form DD -97 05- 09 -'07 13:41 FROM -PC. Septic & Repair 845 - 278 -2318 SHERLITA AMLEK MU, MS, FAAP un m_ NC`ommissioner of Health LORETT'A MOLINARI, RN, MSN Associate Commissioner of Health DEPARTMENT OF HEALTH I Geneva Road, Brewster, New York 10509 REQUEST FOR FIELD TESTING All information below must be f completed prior to any scheduling T -431 P003/004 F -733 ROBERT J. BOND] Cowry Executive ROBERT MORRIS, PE Director of Environmental Health DATE: /0 i ENCYINEtR OR FIRM: Cr (�. PHONE #• ] 8 3 13 PERSON TO CONTACT: ❑ NEW CONSTRUCTION REASON: DEEPS: ❑ EPAIR PROGRAM ❑ ADDITION PROGRAM PERCS: PUMP VEST: ❑ ROAD/STREET: TOWN: hr7 TAX MAP #:��y_� SUBDIVISION: OWNER•' S LOT #: NYCDEP CRITEIUA FOR JOINT REVIEW AND 'WITNESSING OF SOIL TESTING YES NO O Proposed SSTS withba the drainage bashm of West Branch or Boyds Corner Croton Pails Reservoirs. 0, proposed SSTS within 500 feet-of a reservoir, reservoir stem or coiztrol lake. O Proposed SSTS within 200 feet of a watelrcourse or a DEC wetland. o Proposed SSTS design flow greater than 1000 gallons /day or SPD + S Perrart required. 0 proposed SSTS for a Colninercial Project. it is the responsibility of the design professional to provide the above, information prior.to soil testing. The Department vvill determine the NYCDEP project status (Joint or Delegated) based on the response. If you answered Yes to any of the questions, NYCDEP must witness the soil tests. This Department will coordinate .a matually suitable time for field testing with the Desigia Professional and NYCDEP. If a project .has been determined to be Delegated based on the above response and then subsequent information ixldica►tes NYCDEP is required to witness the soil tests, it will be the sole responsibility of the design professional to schedule re- witnessing of the soil testing with NYCDEP. IFOR COLNTY USE ONLY DATE: TZM : COMMP,N•TS: rya FOMMEotesrnAcxLr Environmental1i]ealth (845) 278 -6130 Fax (845) 278 -7921 Water Supply Section (845) 225 -5186 Fax (845) 225. -5418 Nursing Services (845) 278 -6558 Fax (845) 278 -6426 WIC(845)278-6678 Nursing Home Care Fax (845) 278 -6085 Early Intervention/Preschool(945) 278 -6014 Fax(845)278-6648 05- 09 -'07 13;41 FROM -PC. Septic & Repair 845 -278 -2318 T -431 P004/004 F -733 /, , � . f � o'r e— -D r. ��q.r SHERLITA AMLER, MD, MS, FAAP Commissioner of Health LORETTA-MOLINARI, RN, MSN Associate Commissioner of Health DEPARTMENT OF HEALTH 1 Geneva Road, Brewster, New York 10509 -LA4 s4e��L* D ROBERT J. BONDI County Executive ROBERT MORRIS, PE Director of Environmental Health TO: DEPARTMENT OF ENGINEERING AND DESIGN REVIEW PRIORITY - SEPTIC REPAIR DELEGATION STATUS FOR SUBSURFACE SEWAGE TREATMENT SYSTEM PROGRAM PROJECT: TOWN:T_5t�� JOINT REVIEW SUB'D APP DATE NOTICE OF COMPLETE APPLICATION: DATE: e-7 0 % ❑ Within the drainage basins of West Branch, Boyds Corner Reservoirs or Croton Falls. ❑ Within 500 feet of a reservoir, reservoir stem or control lake. L Within 200 feet of a watercourse or a DEC wetland and appearing on a subdivision (( map approved after December 31, 1992. ❑ Design flow greater than 1000 gallons/day. ❑ Commercial SSTS. jtreviewrepair Environmental Health (845) 278 -6130 Fax (845) 278 -7921 Water Supply Section (845) 225 -5186 Fax (845) 225 -5418 Nursing Services (845) 278 -6558 Fax (845) 278 -6026 WIC (845) 278 -6678 Nursing Home Care Fax (845) 278 -6085 Early Intervention /Preschool(845)278 -6014 Fax(845)278 -6648 ENGINEERING REPORT PROPOSED SEWAGE TREATMENT SYSTEM REPAIR JUNTA RESIDENCE 200 LAKE SHORE DRIVE TOWN OF PATTERSON, PUTNAM COUNTY, NEW YORK SEPTEMBER 2007 WARNING: IT IS A VIOLATION OF SECTION 7209, SUBDIVISION 2, OF THE NEW YORK STATE EDUCATION LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER OR LAND SURVEYOR TO ALTER IN ANY WAY, ANY PLANS, SPECIFICATIONS, PLATS OR REPORTS TO WHICH THE SEAL OF A PROFESSIONAL ENGINEER OR LAND SURVEYOR HAS BEEN APPLIED. COPYRIGHT 2007 DESIGN CONCEPTS ENGINEERING, P.C. Prepared by: Design Concepts Engineering, P.C. John A. Kalin, P.E. 3 Memorial Avenue Pawling, NY 12564. s•��. ; - . r �L / r r/ Submitted herewith is a report containing the engineering design data relative to the emergency repair of a failed Sewage Disposal System (SDS) to serve a single family residence within the Town of Patterson, Putnam County, New York. PROJECT DESCRIPTION: The parcel to be serviced by the proposed SSTS is located at 200 Lake Shore Drive in the Town of Patterson. The parcel is identified on the Town Tax Maps as Grid # 25.49 -1 -37. The building is an existing 1 story structure with two (2) bedrooms. The existing septic has completely failed and is.surface discharging. The building is supplied with water from a individual well. GENERAL DESCRIPTION OF SYSTEM: The lot currently has an SSTS which consists of a metal septic tank and a limited leach pit discharge. There is also a drywell on the north side of the parcel adjacent to the well. Effluent has been surface discharging in the lawn and is therefore in failure. Several test holes were excavated and witnessed by representatives of the Putnam County Septic Repair Program(refer to data on plan). During the soils investigation, the SSTS area was found to be a mix of loams and silty sands. There were no indications of water, rock nor mottling in the holes. Utilizing the soil test data, the best area was selected for the treatment system (refer to plan). As this system is a repair, an alternate technology was selected to treat the effluent prior to discharging it into the receiving soil. The peat biofilter system by Puraflow was selected due to its ability to effectively treat effluent in a confined area. The new SSTS shall replace the entire existing. system. The homeowner shall be responsible for any modifications to the interior plumbing in redirecting the effluent line to the south of the residence. Attached please find the proposed plans for the layout of the sewage treatment system. The system is proposed to consist of the following components: 1,000 Gallon Plastic Septic Tank 1;000 Gallon Plastic Pump Chamber with effluent pump 2- Puraflow Peat Fibre Biofilter Modules (blue units) Manufacturer's data was used to size the required number of units. Percolation tests were Engineering Report- Proposed SSTS Repair September 10, 2007 Junta Residence Page 2 performed to size of the gravel bed. Separation distance was maximized from adjacent wells and the lake. Effluent shall be delivered to the units through a force main. The pump chamber shall deliver effluent in 25 gallon doses once per every two hours using a time dose control panel. The panel shall be mounted on the exterior of the building in a weatherproof enclosure with a visual -audio alarm. Sufficient storage capacity has been provided in the pump chamber if a failure occurs. I . In addition to the, SSTS replacement, other improvements have been specified for the project. They are as follows: A surface swale will be installed uphill of the peat units to divert any runoff from the SSTS area. Pick up gutter leaders along the south side of the house and pipe them beyond the SSTS to the west of the parcel. This repair represents the best available solution to the failure, given the constraints of the site. SSTS Design Calculations Project: Junta Residence Location: 200 Lake Shore Drive Patterson, New York 1. DESIGN CONSIDERATIONS 2 Bedroom Single Family Dwelling Emergency Repair of SSTS, Note: Garbage Grinders Shall Not Be Used 2. DESIGN FLOW (Per PCHD Design Standards) 2 bedrooms x 150GPD / bed = 300GPD Use: 300 GPD 3. SEPTIC TANK SIZE For 2 bedrooms use: 1,000 gallon tank Tank shall be plastic (Fralo or appv'd equal) and designed for an H -10 loading. 4. TREATMENT UNITS Perc Rate: 25 min /inch Design Flow: 300 GPD (2 bedroom) Method of Treatment: Puraflow Peat Fibre Units Units Req'd: 1 unit/bed x 2 bed = 2 units Use: 2 units 5. DISPERSAL BED .Provide dispersal bed below treatment units Perc Rate: 25min /inch As per Table 1 in the Puraflow Design manual (6/26/06 ed.), the underlying soil is classified as a Group 2 soil and is set at 1.33 gpd /sf infiltration rate (25 min /in pad). 2 bed x 150 gal /bed / 1.33 gpd /sf = 225 sf Make bed 11' x 21'(231 sf D E S I G N C O N C E P T S E N G I N E E R I N G P C 3 MEMORIAL AVE, SUITE 1 01 , PAWLING, NY 12564 PH: 845- 855 -2000 • FX: 845 -855 -2605 E: JKALINOVERIZON.NET Junta SSTS - Repair Calculations Putnam County Septic Repair Program Page 2 September 10, 2007 .6. DOSING VOLUME As per the manufacturer, the system shall be time dosed 12.5 gal /unit every two hours.. 2 units x 12.5 gal /unit = 25 gal dose /2 hrs PUMP CHAMBER: PUMP DESIGN Pump calculations: Daily design flow: 300 gpd Dose volume: 25 gallons Friction Head: Pipe type /size: 1 W' polyethylene Length: 20 LF H -W coefficient: 120 Assumed flow rate: 30 gpm Loss ( @30GPM): 6.26/100' (per Goulds) Equivalent Lengths: Straight Length 20 LF Fitting loss (use 1 Y2" dia) 90° elbow (2): . 4.3 x 2 45° elbow (2): 2.0 x 2 Quick disconnect (1): 4.3 x 1 Discharge (1): 1.5 x 1 Cleanout (3): 2.0 x 3 Ball Valve (1): 54.0 x 1 Check Valve (1): 11.0 x 1 Nozzle Losses: 50.0 x 1 Total length: 159.4 LF = Use: 160 LF Total Dynamic Head: Total dynamic head = static,head + friction head Friction Head: D E S I G N C O N C E P T S E N G I N E E R I N G P C 3 MEMORIAL AVE. SUITE 1 01 , PAWLING, NY 12564 PH: 845 -855 -2000 • FX: 845 -655 -2605 E: JKALINOVERIZON.NET Junta SSTS - Repair Calculations Putnam County Septic Repair Program Page 3 September 10, 2007 Friction head = Equivalent length x Head Loss /100 ft of pipe 160LF x 6.26FT =.1 0.02 ft 100FT Static Head: Static head = Elev at Unit - Elev. at Pump 98.5 -95 = 3.5 ft Total Dynamic Head: 10.02 + 3.5 = 13.52 FT Use: 14 ft Pump specifications: Using the total dynamic head of 14 ft, a Goulds Effluent Pump Series PE, Model PE31, .33 HP, 115V, has been selected. This pump can deliver approximately .32 gal /min against. 14 ft of total head. Refer to attached sheets for pumps specifications and chart. Cycle time: Dose = 25 GAL /CYCLE Pump rate = 32 GPM NOTE: THE PUMP WILL BE CALIBRATED IN THE FIELD TO DELIVER 10 GAL /MIN BY USE OF A FLOW BYPASS (REFER TO PLAN). Drawdown / Float Switches: Tank capacity: 28.0 gal /in of depth of 1,000 gallon Fralo tank) Drawdown = Dose/Vol per Depth of tank 25 gal / 28 gal /in = .89 inches or 7/8" Per design, the pump shall operate on a timer designed to deliver a 25 gallon dose every 2 hours. There shall be a pump enable float set at 3" off of the D E S I G N C O N C E P T S E N G I N E E R I N G P C 3 MEMORIAL AVE. SUITE 1 01 , PAWLING, NY 12564 PH: 645 -655 72000 0 FX: 845 -655 -2605 E: JKALINOVERIZON.NET Junta SSTS - Repair Calculations Putnam County Septic Repair Program Page 4 September 10, 2007 chamber floor. The alarm float will beset at 10.0" above the tank floor. Emergency storage volume capacity is 720 gallons. D E S I G N C O N C E P T S E N G I N E E R I N G P C 3 MEMORIAL AVE. SUITE 1 01 , PAWLING, NY 12564 PH: 845 -855 -2000 • FX: 845- 855 -2605 E: JKALINOVERIZON.NET PUTNAM COUNTY DEPARTMENT OF HEALTH DIVISION OF ENVIRONMENTAL HEALTH SERVICES DESIGN DATA SHEET - SUBSURFACE SEWAGE TREATMENT SYSTEM Owner - J V j� Address ZCO DRIVE Located at (Street) lyo L,A9r,6 VKIVS Tax Map l� Block I Lot (indicate nearest cross street) Municipality 's T ai Watershed MsT L�i9�i�NGi� SOIL PERCOLATION TEST DATA Date of Pre - soaking! O Date of Percolation Test _ NOTES: 1. Tests to be repeated at same depth until approximately equal percolation rates are obtained at each percolation test hole. (i.e. <_ 1 min for 1 -30 min/inch, <_ 2 min for 31 -60 min/inch). All data to be submitted for review. 2. Depth measurements to be made from top of hole. Form DD -97 Pg. 1 of 2 TEST PIT DATA DESCRIPTION OF SOILS ENCOUNTERED IN TEST HOLES DEPTH HOLE NO. t)T • I HOLE NO. DT Z HOLE NO. G.L. 0.51 �� TO�SO((� �tiZN °TOP O(c� 1.0' 36„ I.4,AM 1.5' 2.0' Z5�%�Zu I.014M 2.5' 3.0' 3.5' S somsS ONE Sti8N" SI(-TY coA S6 4.0' SAND 4.5' 5.0' 5.5' 6.0' 6.5 $T Ali 7.0' 7.5' 8.o' 8.5' 9.0' 9.5' 10.0' Indicate level at which groundwater is encountered Noi 15N000MT6 ;D Indicate level at which mottling is observed NOT 0&;F- 9VE12 Indicate level to which water level rises after being encountered M (R Deep hole observations made by: J•r -AL-IN, M. gup7-jN&U, D.s4EDt -0 Date 3.2$'07 Design Professional Name-'Jo I-tN A I-A wt-A P. E . Address: 1%. ENC4IM66 IIVA Pc, 3 MEM0F -(At AVE SVIT1 lo( PAwLCNLn NY Izs6l-f Signature: I - Z Tz , Design Professional =s Seal Ln'44* ITT APPLICATIONS Specially designed for the following uses: •,Mound Systems • Effluent/Dosing Systems • Low Pressure Pipe Systems • Basement Draining • Heavy Duty Sump/ Dewatering SPECIFICATIONS Pump — General: • Discharge: 1'h" NPT • Temperature: 1040F (4000 maximum, continuous when fully submerged. • Solids handling: 1/2" maximum sphere. • Automatic models include a float switch. • Manual models available. • Pumping range: see performance chart or curve. PE31 Pump: • Maximum capacity: 53 GPM • Maximum head: 25' TDH • Maxim011 • Maio • Maxi • un METERS FEET 401 35 to 30 0 Q 25 V Z20 O X15 10 GPM GOULDS PUMPS Residential Water Systems MOTOR General: • Single phase • 60 Hertz • 115 and 230 volts • Built-in thermal overload protection with automatic reset. • Class B insulation. • Oil -filled design. • High strength carbon steel shaft PE31 Motor: • .33 HP 3000 RPM • 115 volts • Shaded pole design Motor. • A 0 RPM • an volts . • PSC design >51 Motor. H RPM 230 volts desi AGENCY LISTINGS 70 GPM CR h ead.3 us Tested to UL 778 and CSA 22.2 108 Standards By Canadian Standards Association File AR38549 DELS: PE31, PE41, 33, .40, .50 —► 2 GPM 1 FT 0 5 10 15 m3/h CAPACITY Goulds Pumps is ISO 9001 Registered. K, ol ITT GOULDS PUMPS Residential Water .Systems PERFORMANCE RATINGS DIMENSIONS PE31 PE51 (All dimensions are in inches. Do not use for construction purposes.) Total Head (feet of water) GPM 5 52 10 42 15 29 20 16 25 0 PE41 Total Head (feet of water) GP 10 Amps 15 0,59 20 jr 50 25 39 Maximum Solids Size 26 35 8 Total Head (feet of water) ?GiOP Volts Amps Minimum Circuit Breaker 57 Xr 46 Discharge Connection 33 Maximum Solids Size 16 PUMP INFORMATION 1 SCHARGE .1 Order No. HP Volts Amps Minimum Circuit Breaker Phase h Float Switch Cord Len Length Discharge Connection Minimum Basin Diameter Maximum Solids Size 'Shipping Weight Ibs/kg PE31 M 5 11 1Z J 20 Manual / No Switch Piggyback Float SWItC 20' 1.5" 18" 3- 31/14.1 Manual / No Swi Piggyback float itch Manual / N witch Piggyback oat Switch Sr fff 2e Manu / No Switch Piggy6ack Float Switch anual / No Switch �E53PT /Piggyback Float Switch Permit # Robert J. Bondi Cris Dellaripa County Executive K" Septic Repair Inspector Edward A. Barnett Michele Palermo Watershed Information Coordinator Office Manager PUTNAM COUNTY SEPTIC REPAIR PROGRAM 100 Rte. 312 Bldg. #4 Brewster, NY 10509 /( Date: V121 I 0 cQ PCDOH Attn: Michael Budzinski 1 Geneva Rd. Brewster, NY 10509 Dear Mr. Budzinski; We wish to report that the following job: Name c> U''+ ��-- Address ?— 0 KG Tax ID# .2-.r. V g % —3 9 has been completed as per the approved drawings. As -Built Attached: Yes. No I MA S' d' CC: Dan Shedlo, P.E. ) e- -d _S_1' _t'" !�L s Telephone: (845) 278 -8313 Fax: (845) 278 -2318 Al =24' 2 =25" 3 =20" 4 =30' B1 =11" 2 =14' 3= 7' 4 =11' PUMP IH HOLE s1 PUMP TANK SWISHER 200 LAKESHORE Dr: PATTERSON PROJECT #080107 4" SDR#35 SEPTIC TANK SEPTIC CLEAHOUT IH HOLE #3 s Y i NOTE• ; BRAiI/Q / EX ,. ST TANKAN ON ROAD I PUMPED BYtiA NYSO E I HAULER AND THEN;116;1 R c w, EDGE Of m ,Zo, PAVWENT Sri rh E � A' ROCK AREA 24'MAPLE STUMP PAVED a�i r b Hav�W / ,SEPTIC DT -1 LEAKAGE 0$ ✓ I E,11' 4 M %4 If OF AV """20 5 IRON ROD °MNT 'SM`s'rr. FOUND t,v'r' ��rt ASR. P r— 1 CO A �4D M srocKADE, a� } NC. / /f WALK ONE s rORY HOUSE PROVIDE I ��, /��� /, CONC. PICK UP LGUT >IEIL' 0 k /�� ,� ff. 103.4 // : AND PIPE;,TO"fiQUs 'ONE \ �� r DT -2 Ull I s u c 4 "0 PVCa SDR ,35,PIPEl PAW % �S 1 AND CLEAN OUTS N:t- %MIN ;PIy�il4�, t ice" "y� Rh Z.O.B. 1000 GALLON PLASTICS SEP11Gr REFERL° T0il� DETAIL 20VIDE MINOR FILL VELING PURPOSES )R LE CIiAIN UNK a FENCE A^' CUF IN g — PEAT BIOFILTER MODULES cONCRErE 1.0% MIN PITCH TO TANK ;EFER TO DETAILS) " 4 0 PVC SDR -35 PIPE NOTE: '" EXISTIN x21'x6 LEVEL GRAVEL PAD G SSTS FIE iEFER DETAIL) 1000 GALLON PLASTIC PUMP SHALL ;BE, ABANDC CHAMBER. REFER TO DETAIL IN ACCORDANCE „V! 5 "0 PVC SCH 40 FORCE MAIN NYCDEP� REG;ULATI ZEFER TO DETAIL) SURFACE SWALE REMOVED. COMPO� REFER TO DETAIL REPLACED WITH S FILL CONTAINING I FINES AND THEN SILT FENCE (TYP•) oes �o, TICj' SITE PLAN SCALE: I inch = 20 feet SHERLITA AMLER, MD, MS, FAAP Commissioner of Health LORETTA MOLINARI, RN, MSN Associate Commissioner of Health DEPARTMENT OF HEALTH I Geneva Road, Brewster, New York 10509 Chris Dellaripa Putnam County Septic System Repair Program 100 Route 312, Building # 4 Brewster, NY 10509 Dear Mr. Dellaripa: ROBERT J. BONDI County Executive ROBERT MORRIS, PE Director of Environmental Health December 31, 2007 Re: Septic Repair Permit (WS- 223 -07) for Junta at 200 Lakeshore Dr. (T) Patterson, T.M. # 25.49 -1 -37 This Department, in conjunction with the NYCDEP, has received and reviewed the submitted repair permit, engineer's report and plans for the above referenced project. The repair permit is hereby approved with the following conditions. 1. The owner must maintain an effective septic pump -out schedule until the subject repair is completed. 2. The septic system repair shall be fully constructed and completed in compliance with the approved permit and engineering plans. 3. The Health Department shall be notified when constructions starts on the system and also notified prior to backfill of the system. 4. The subject repair cannot be used as a.system to provide sewage treatment for new construction or expansions on the site. Should you have any questions concerning this matter, please feel free to contact this office. Respectfully, Michael J. Director of MJB:kly cc: J. Kalin, PE D. Shedlo, DEP MAB Environmental Health (845) 278 -6130 Fax (845) 278 -7921 Water Supply Section (845) 225 -5186 Fax (845) 225 -5418 Nursing Services (845) 278 -6558 Fax (845) 278 -6026 WIC (845) 278 -6678 Nursing Home Care Fax (845) 278 -6085 Early Intervention /Preschool (845) 278 -6014 Fax (845) 278 -6648 DIVISION OF.ENVIRONMENTAL HEALTH SERVICES R SEWAGE TREATMENT S Internal Use EPAIR PERMIT # U L'4 Repair Permit issued in last 5-years U Not in Watershed ❑ ❑ Repair within Boyd's Corners, W. Branch or Croton Falls Res. ❑ Delegated ❑ ❑ Repair within 200 ft. of a watercourse or DEC - mapped wetland ❑ Joint Review SITE LOCATION � oa ,�,4 Y )ym br TOWN TM # yRJ-; OWNER'S NAME 'PHONE # �3 MAILING ADDRESS r$ an1L APPLICANT Name & Relationship (i.e., owner, tenant, contractor) DATE %,!I �ja 7 FACILITY TYPE,' PCHD COMPLAINT # PROPOSED INSTALLER PHONE # ADDRESS REGISTRATION /LICENSE # Proposal (include a separate sketch locating the house, property lines, all adjacent wells within 200 feet of repair and the location of existing and proposed system) NOTE: The Department may require submittal of proposal from licensed professional depending on the nature and extent o the repair. I, as owner,agree to the conditions stated on this form SIGNATURE TITLE DATE (owner) I, the septic installer, agree to comply with the conditions of this. permit for the septic system repair SIGNATURE C, r-' TITLE - r DATE, %�j (installer) Proposal. approved with the following conditions: 1. Procurement of any Town Permit, if applicable. 2. Submission of as built repair sketch by the septic system installer within 30 days of the repair, in duplicate showing: a. Owner's name, Site Street Name, Town and Tax Map number b. Location of installed components tied to two fixed points c. System description (e.g., 1250 gal. Concrete septic tank, etc.) d. Installers' name and phone number 3. System repair to be performed in accordance with the above proposal and conditions 4. The proposed SSTS repair is considered a best fit design and there is no guarantee to the duration at which the completed SSTS repair will function. 5. No completed work is to be backfilled until authorization to do so has been obtained from the Department. INTERNAL USE ONLY P oposal Approved Proposal Denied ❑ nspector's Sig ris e 'tle Date Expiration Da e Repair ro os co fiance with app' aiec od es Yes ❑ No COPIES: PCHD; Owner; Installer PC -RP 99ML Rev, 2/07 OC ENGINEERING., RC December 18, 2007 Mr. Michael Budzinski, P.E. • Putnam County Department of Health 4 Geneva Road Brewster, N.Y. 10509 Re: Junta Residence SSTS Repair 200 Lakeshore Drive Patterson, New York TM# 25.49 -1 -37 Dear Mike: have reviewed your comment letter regarding the above referenced project. With respect to the location of, the percolation test performed by Repair Program Staff, while it is not in within the footprint of the proposed SSTS repair, I feel that the test is representative of the onsite soils. In review of the deep test pit data, it is evident that the receiving soils underlying the SSTS area are relatively uniform to those near the percolation test, which is approximately 27 feet away. In addition, the percolation test data has been conservatively applied in the sizing of the gravel bed below the peat units, which was slightly increased in size (231 sf vs. 225 sf) from the manufacturer's required dispersal area. It is with this understanding that I feel that the percolation test is sufficient for the design of the SSTS repair. If you have any questions, feel free to call me at your convenience. I can be reached at (845) 855 -2000. Y '`� P • Kq 09 Y, !JQhriA`:` Kalih�� ellaripa, PC Septic Repair Program C:\design concepts\ projects\ PCSRP\ SWISHER \COORESP\121807.resp.Itr.wpd D E S I G N C O N C E P T S E N G I N E E R I N G P C 3 MEMORIAL AVE. SUITE 1 01 , PAWLING, NY 12564 PH: 845- 855 -2000 • FX: 645- 855 -2605 E: JKALINOVERIZON.NET ®C ENGINEERING, PC December 18, 2007 Mr. Michael Budzinski, P.E. Putnam County Department of Health 4 Geneva Road Brewster, N.Y. 10509 Re: Junta Residence SSTS Repair 200 Lakeshore Drive Patterson, New York TM# 25.49 -1 -37 Dear Mike: have reviewed your comment letter regarding the above referenced project. With respect to the location of the percolation test performed by Repair Program Staff, while it is not in within the footprint of the proposed SSTS repair, I feel that the test is representative of the onsite soils. In review of the deep test pit data; it is evident that the receiving soils underlying the SSTS area are relatively uniform to those near the percolation test, which is approximately 27 feet away. In addition, the percolation test data has been conservatively applied in the sizing of the gravel bed. below the peat units, which was slightly increased in size (231 sf vs. 225 sf) from the manufacturer's required dispersal area. It is with this understanding that I feel that the percolation test is sufficient for the design of the SSTS repair. If you have any questions, feel free to call me at your convenience. I can 15 -2000. 'C Septic Repair Program C: \design concepts\ projects\ PCSRP\ SWISHER \COORESP \121807.resp.ltr.wpd D E S I G N C O N C E P. T S E N G I N E E R I N G P C 3 MEMORIAL AVE. SUITE 1 01 , PAWLING, NY 12564 PH: 845 - 655 -2000 • FX: 845 -855 -2605 E: JKALINOVERIZON.NET SHERLITA AMLER, MD, MS, FAAP Commissioner of Health LORETTA MOLINARI, RN, MSN Associate Commissioner of Health ROBERT J. BONDI County Executive ROBERT MORRIS, PE Director of Environmental Health DEPARTMENT OF HEALTH 1 Geneva Road, Brewster, New York. 10509 Design Concepts Engineering John Kalin, P.E. 502 Gardner Hollow Rd. Poughquag, NY 12570 Dear Mr. Kalin: November 2, 2007 Re: Proposed SSTS Repair for Junta at 200 Lakeshore Dr. (T)Patterson, TM #25.49 -1 -37 This Department, in conjunction with the NYCDEP, has received and reviewed the submitted application and plans for the above referenced project and the following comments are offered for your consideration. 1. The percolation test was not conducted in the proposed SSTS area. The percolation test is to be redone in the proposed peat unit area and the resulting rate used for the SSTS repair design calculations. Upon completion of the above, this Department will continue its review. Kindly advise us if there are any questions. Respectfully, MJB:lm cc: D. Shedlo, DEP Michael J. Ndzinski Director of VsnRineerh Environmental Health (845) 278 -6130 Fax (845) 278 -7921 Water Supply Section (845) 225 -5186 Fax (845) 225 -5418 Nursing Services (845) 278 -6558 Fax (845) 278 -6026 WIC (845) 278 -6678 Nursing Home Care., Fax (845) 278 -6085 Early Intervention /Preschool(845)278 -6014 Fax(845)278 -6648 November 1, 2007 Mr. Michael Budzinski, P.E. Putnam County Health Department 1 Geneva Road Brewster, New York 10509 Re: Junta Septic Repair — Putnam County Septic Repair Program ( PCSRP) (T) Patterson, Putnam County East Branch Reservoir Drainage Basin DEP Log # 2007 -EB- 1004 -DJR.I Dear Mr. Budzinski: This letter is to inform you that the New York City Department of Environmental Protection (DEP) has no objection to the approval of the above - referenced activity, subject to the following conditions: 1. The owner must maintain an effective septic tank pump -out schedule until the subject repair is completed. 2. The subject repair cannot be used as a system to provide sewage treatment for new construction or expansions on this site. This determination is based on the review of submitted documents including the drawings titled "SSTS Repair Plan - Junta Residence ", 200 Lakeshore Drive, Patterson, New York, dated 8/1/07. If you have any questions, I may be reached at (914)742 -2055. Sincerely, Danny Shedlo, P.E. Civil Engineer III Wastewater Design Review EOH xc: Michael Meyer, NYCDEP EOH Planning Edward Barnett, PCSRP Watershed Information Coordinator Chris Dellaripa, PCSRP Inspector Roger Sokol, P.E., NYSDOH i �.?e �artmenfi��olr? :` w- . • '' •: Protect[gr� ':,:' ' .. a:�. pia. �..,+: �r, �:.., .,..r...,,mao,.ro:�,,:�:,.,«�:, r C 1.=s Avenue vwhalla; N6v York ''� 1454336; ' . • ;,` ' �+ r , "EMilyioyd -r _ r Buaau,&Wat4*.- 6jW0_, '*,'> .. -D�p�ty�Eoiriml��fbme�= =• :,-�} ' x g'154j 4 S . JA:l:.�4Tr'�•:�,�•,"r,••,�..f Ham': •:•. A•Y,..:Ci'- .nr:n. � y •.Yf]f�i • I • www.r•nTc.Sor,ldep � r • H E t P Fax:914 -773 -0343 November 1, 2007 Mr- Michael Budzinski, P.E. Putnam County Health Department 1 Geneva Road Brewster, New York 10509 Nov 1 2007 16:06 P.01 Re: Junta Septic Repair — Putnam County Septic (T) Patterson, Putnam County East Branch Reservoir Drainage Basin DEP Log # 2007 -EB- 1004 -DJR.1 Dear Mr. Budzinski: This letter is to inform you that the New York City Environmental Protection (DEP) has no objection to referenced activity, subject to the following conditiv I 1. The owner must maintain an effective septic until the subject repair is completed. 2. The subject repair cannot be used as a system treatment for new construction or expansions This detezzoination. is based on the review of subrnitt the drawings titled "SSTS Repair Plan - Junta Residf Drive, Patterson, New York, dated 8/1/07. Program (PCSRP) epartmeIlt of he approval of the above- pump -out schedule to provide sewage on this site. documents including of f, 200: Lakeshore If you have any questions, I may be reached at (914)42- 2055. Sincerely, 4 �ti Danny Shedlo, P.E. Civil Engineer RI Wastewater Design Review EOH xc: Michael Meyer, NYCDEP EOH Planning Edward Barnett, PCSRP Watershed Infon Chris Dellaripa, PCSRP Inspector j Roger Sokol, P.E., NYSDOH Coorcl xiator r. -� e , t � , t _ . 1. i,t